Seite 1 - Outdoor Speed Dome Camera

Outdoor Speed Dome CameraInstallation ManualAccessoriesCA-510GCA-510WCA-510CCA-510P25CA-510P50CA-510PMLCA-510PMSCA-510PA25CA-510PA50CameraCM-512www.op

Seite 2

10 INTRODUCTION OVERVIEW With a weather resistant design, the Integrated High Speed Dome Camera is applicable for outdoor installations. The dome cam

Seite 3 - 31515AB 3

31515AB 11 NOTES:

Seite 4 - Precautions

12 GETTING STARTED BOX CONTENTS Before proceeding, please check that the box contains the items listed here. If any item is missing or has defects,

Seite 5 - Regulation

31515AB 13 DOME SETUP AND CABLE CONNECTION Before installing or connecting the dome camera, please refer to this section and complete preparations f

Seite 6 - DO NOT OPEN

14 4. Using both hands, gently press the dome cover. Do not press the cover from the dome. 5. Use screws to affix the dome cover to the body.

Seite 7 - Standard Warranty

31515AB 15 Dome Camera Setup Before connecting the dome camera to other CCTV devices, please complete the camera ID and communication switch setting

Seite 8 - TABLE OF CONTENTS

16 RS-485 Switch Setting Switch SW1 RS-485 Setting SW2 SW3 Termination SW4 Line Lock SW5 System Initialization SW6 Reserved RS-485 is the inter

Seite 9 - 31515AB 9

31515AB 17 Dome Control Protocol Setting Define the protocol you are going to use based on the devices of your surveillance system. Generally, use o

Seite 10 - INTRODUCTION

18 Power Connector Refer to this diagram for power connector definition before wiring. 1 AC IN + 2 Frame GND 3 AC IN - Apply Alarm I/O The CM-5

Seite 11 - 31515AB 11

31515AB 19 RS-485 Connector Definition The dome camera uses the RS-485 interface to communicate with a connected control device. Connect a control

Seite 13 - Preparations for Dome Setup

20 Grounding Recommendation The GND wire must be directly connected to the middle pin of the AC24V power connector. Failure to connect the ground can

Seite 14

31515AB 21 DOME DIMENSIONS The dome dimensions are Ø172 x 228.71mm (6.77 x 9.0 inches) and Ø191.97 x 282.11mm (7.5 x 11.1 inches) with the sunshield

Seite 15 - Dome Camera Setup

22 OPTIONAL ACCESSORIES Dome Camera Accessories Transparent/Smoke Cover Part Number: CA-510-DT Mounting Accessories Wall Mount Bracket (w/ Anti Drop

Seite 16 - Camera ID Setting

31515AB 23 Ceiling Mounting with Pole The pole is available in two lengths: 25 cm and 30 cm. Items Needed: • Dome Camera • Ceiling Pole Accessory

Seite 17 - 31515AB 17

24 Wall Mounting with Wall Mount Bracket Items Needed: • Dome Camera • Wall Mount Bracket or Long Wall Mount Bracket • Waterproof Gasket (supplied

Seite 18 - Apply Alarm I/O

31515AB 25 4. Attach the wall mount bracket to the wall with the appropriate screws and screw anchors (not provided). 5. Attach the waterproof ga

Seite 19 - RS-485 Connector Definition

26 Wall Mounting with Corner Mount The corner mount must be used in conjunction with the wall mount bracket. Items Needed: • Dome Camera • Wall Mo

Seite 20 - Grounding Recommendation

31515AB 27 Pole Mounting The dome can be mounted on a pole with the small or large direct mounting assembly and a wall mount bracket. Items Needed:

Seite 21 - DOME DIMENSIONS

28 SPECIFICATIONS CAMERA SPECIFICATIONS Model CM-512 Image Sensor 1/4” Sony CCD IP Rating IP66 Type / Format NTCS Wide Dynamic Range Yes Minimum Ill

Seite 22 - OPTIONAL ACCESSORIES

31515AB 29 Model CM-512 Input Voltage 24vAC ± 10% Weight 5.11 lbs (2.3 kg) Dimensions Ø7.5" (190.5mm) x H: 11.1" (282mm) Housing / Dome C

Seite 23 - Ceiling Mounting with Pole

31515AB 3 Outdoor High-Speed Dome Camera (CM-512) Installation Manual Manual Edition 31515AB – AUGUST 2013 ©2013, OPENEYE All Rights Reserved.

Seite 25 - 31515AB 25

31186AA www.openeye.net 1-888-542-1103 © 2012 OpenEye All rights reserved. No part of this publication may be reproduced b

Seite 26

4 Important Safeguards 1. Read Instructions Read all of the safety and operating instructions before using the product. 2. Retain Instructions Save

Seite 27 - Pole Mounting

31515AB 5 Installation and Storage • Do not install the camera in areas of extreme temperatures in excess of the allowable range. ( -58°F ~ 122°F /

Seite 28 - SPECIFICATIONS

6 Warning DANGEROUS HIGH VOLTAGES ARE PRESENT INSIDE THE ENCLOSURE. DO NOT OPEN THE CABINET. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. Caution

Seite 29 - PTZ SPECIFICATIONS

31515AB 7 Standard Warranty OpenEye warrants all new products to be free from defects in workmanship and material under normal use for a period of t

Seite 30

8 TABLE OF CONTENTS Introduction ........

Seite 31 - 31186AA

31515AB 9 NOTES: